| Constellation | GPS, Galileo, SBAS, QZSS, GLONASS or BeiDou |
| Output Signal Level | Adjustable from -73 dBm to -103 dBm |
| RF Constellations | Single Constellation: 1Dual Constellation: 2Triple Constellation: 3 |
| RF ConstellationCentre Frequency | 1575.4/1602.00/1561.098/MHzGPS&GALILEO/GLONASS/Beidou |
| Number of Satellites Observed | All in view |
| Sampling frequency | 16.368 MHz |
| Bandwidth | 9.66 MHz |
| Quantisation | Single Constellation:1 constellation at 1-bit I&Q or at 2-bit I&QDual Constellation:2 constellations at 1-bit I&Q or 1 constellation at 2-bit I&QTriple Constellation:2/3 constellations at 1-bit I&Q or 1 constellation at 2-bit I&Q |
| Data Format | I & Q |
| User Control | 6 Button Membrane Keypad |
| Display | Backlit LCD Dotmatrix |
| Additional Logging | Single Constellation:1 channel Digitized CAN, RS232 or Digital or 2 channels of log file CAN (licence upgrade)Dual Constellation:2 channels of CAN, RS232, Digital or 2 channels of log file CAN + 1/2 channels of digital (RS232/Digi)Triple Constellation:2 channels of CAN, RS232, Digital or 2 channels of log file CAN + 1/2 channels of digital (RS232/Digi) |
| Removable Battery Pack | Single Constellation:Record & Replay version onlyDual and Triple Constellation:Both versions |
| Battery Type | Varta Easypack Li_Polymer 2260 mAh |
| Media Storage Included | 32 GB SD Card & 1 TB USB HDD |
| SD Card Media | Class 10max size 128 GB (FAT32) |
| Active Antenna Voltage Supply | 2.80 – 3.0 Volts |
| Reference Oscillator | 16.368 MHz Temperature controlled +/- 2.5 ppm or OCXO option+/- 0.3 ppm |
| Operating Voltage | 8 V to 30 V DC |
| Power Consumption | Power <16 W |
| Size | 167 mm x 128 mm x 43 mm |
| Weight | 960 g with battery (910 g without battery) |
| Operating Temperature | -20°C to +60°C Note: Battery will not charge below 0°C or above +45°C (charger shuts down outside this range). Unit will shut down outside operating temperature range. |
| Storage Temperature | –20°C to +60°C Note: Battery will discharge whilst in storage and discharge rate will increase at higher storage temperatures. |
The LabSat 3 dimensions in millimetres.
Image missing