Issues Accessing LabSat 4 or LabSat 3 Wideband Via Ethernet

Updated on Mar 4, 2026

If you encounter issues accessing LabSat 4 or LabSat 3 Wideband via Ethernet, you may resolve the problem by enabling insecure guest logons

How to enable access to the internal SSD:

  1. Press Win + R to open the Run dialogue.

  2. Type gpedit.msc and click OK.
     

Run dialogue with gpedit_msc
  1. In the Local Group Policy Editor, navigate to:
    Computer Configuration > Administrative Templates > Network > Lanman Workstation
     


Local Group Policy Editor_ComputerConfig
Right Arrow
Local Group Policy Editor_AdminTemplates
Local Group Policy Editor_ComputerConfig
Right Arrow
Local Group Policy Editor_AdminTemplates
Local Group Policy Editor_Network
Right Arrow
Local Group Policy Editor_LanManWorkstation
Local Group Policy Editor_Network
Right Arrow
Local Group Policy Editor_LanManWorkstation
LeftDown Arrow
  1. Open Enable insecure guest logons.
     

Local Group Policy Editor_EnableInsecureGuestLogons
  1. Select Enabled and click OK.
     

Local Group Policy Editor_EnableInsecureGuestLogons_Enabled

Once this policy is applied, you should be able to access the internal SSD.

If you are still having issues, please contact Racelogic Support