Quick Start Guide

Updated on Mar 4, 2026

You can find the full User Guide for the NTRIP Base Station here

 

Product CodeQtyDescription
VBNBSNRG-V21NTRIP Base Station unit (Ext. GNSS antenna)
RLCAB1171USB A to USB B (Micro) - 1.8 m
RLCAB2031VBNBS AC Power Cable
RLVBACS067-51GNSS Ground Plane Antenna + 5 m cable

 

Product CodeQtyDescription
VBNBSNR-V21NTRIP Base Station unit (No Radio)
RLCAB1171USB A to USB B (Micro) - 1.8 m
RLCAB2031VBNBS AC Power Cable

 

Product CodeQtyDescription
VBNBS24-V21NTRIP Base Station unit (Ext. GNSS antenna)
RLCAB1171USB A to USB B (Micro) - 1.8 m
RLCAB2031VBNBS AC Power Cable
ANT24CWHWSMA1GNSS Ground Plane Antenna + 5 m cable
NTRIP Base Station_line drawing_Display.png

The front panel of the NTRIP Base Station has a display that provides feedback about the boot sequence and the operating status. 

When the boot sequence has been completed, the display will switch to a sequence of status screens that automatically scroll on a 5-second timer. The display will show the latest information available for:

  • Wi-Fi SSid & IP Address / Basestation SSid & IP Address (10.10.10.1 default)
  • Position: Position status / saved location name (if using) / NTRIP status / Satellites
  • Location: Saved location name (if using) / Latitude & Longitude of base station's surveyed position
  • Battery Status: Percentage value between 0 and 100% and text which says charging battery or fully charged.

If the unit is performing a survey, it will replace the position status with:

  • Surveying: Time remaining / Estimated Error / Satellites

On the left side of the NTRIP Base Station, you will find the following:

The power button

Press the power button to power on the NTRIP Base Station. 
The power button LED will indicate if the unit is on or charging. 

The antenna port

You can use the antenna port to connect external antennas (VBNBS-NRG) or Radio Antennas (VBNBS-24).  

The Hirose connector

The Hirose connector is the serial and power port for the NTRIP Base Station. 

This is where you:

  • Connect the power supply to power/charge the NTRIP Base Station unit. 
  • Connect the external radio with the serial/power connection cable to broadcast the RTK corrections via an external radio. 

The Status LED  

The Status LED will provide indication of the current status of the NTRIP Base Station as described in the LED behaviour section of this User Guide. 

NTRIP Base Station_Hardware Overview

The right side of the NTRIP Base Station has a compartment door fixed to the unit with 4 screws (M3 Hex). 

  • This compartment is where you find the SIM card slot if you want to use the internal 4G modem via a Standard SIM card to acquire the NTRIP correction messages from the server. 
    Note: If you want to use the internal 4G modem, you must use your own Standard data SIM card.
  • This compartment also has a USB port that you can use to connect to a PC to upgrade the firmware. 
NTRIP Base Station_Hardware Overview_Right Side

The bottom of the unit has the mounting point for the NTRIP Base Station, a 5/8" UNC point, that you can use to mount the unit during installation. 

 

NTRIP Base Station_Hardware Overview_bottom

The rear of the NTRIP Base Station has the product label, which will provide the information about the product, such as the product code, which indicates the product name/type and variant, compliance, access to user documentation, voltage information, etc.

NTRIP Base Station_line drawing_Label

The unit/GNSS antenna must be placed in a position away from any buildings, trees, walls, high-wire fences or any other obstacles that could block or reflect satellite signals.

Place the unit/GNSS antenna at the highest available spot and/or on a tripod to ensure the best possible satellite reception. Make sure the legs of the tripod are fully extended to give maximum height.

If you intend to install the NTRIP Base Station in a permanent rooftop location, you must ensure that the unit/GNSS antenna is not shadowed by any other parts of the building or nearby objects.

 

gps1 (1)
gps2 (1)
gps1 (1)
gps2 (1)

If you are using an external antenna, it should be connected before you power on the NTRIP Base Station. 

The radio antenna for the NTRIP Base Station must be placed in the highest available position to realise the maximum possible transmission range. Where possible, the position should be close to the centre of the area over which the system is to be used.

Example:

If the system is to be used at a test or race circuit, mount the antenna tripod in the centre of the circuit to give equal radio coverage to all points on the circuit.

If your NTRIP Base Station is used in temporary locations, we recommend that you use a telescopic mast to raise the radio antenna as high as possible. 

The NTRIP Base Station will power on when you press and hold the Power button for 1 second when the unit has sufficient charge and/or is connected to an external power source. 

The unit will power off when: 

  • You press and hold the Power button for 3 seconds

    OR
     
  • The unit is not connected to an external power source AND it has not seen a valid satellite signal for X minutes. 

LED #

When the NTRIP Base Station is charging, the Power button LED will be illuminated. 

LCD Display #

The LCD display will cycle through different information, including the current battery level: 

LCD_Battery Status_350px
Configuration Page #

When you have connected to the NTRIP Base Station via Wi-Fi, you can find the Battery Status information in the Configuration portal for the connected unit.

Battery_Status
Battery Charge Status #

The available Battery Charge Statuses are:

  • Not Charging
    The battery is not charging.
     
  • Charging
    The battery is charging. 
Relative State of Charge (%) #

The Relative State of Charge field displays the percentage of charge currently in the battery. 

Run Time to Empty #

The Run Time to Empty field displays the estimated time until the battery is depleted. 

When the unit is charging, the Run Time to Empty will display N/A.

The NTRIP Base Station configuration is done via an HTML browser and, as such, it requires a Wi-Fi-enabled device​.

  1. Identify the NTRIP Base Station SSID on the list of available Wi-Fi networks on your device.

    This will be “RL Basexxxxxx” where xxxxxx is the serial number of the NTRIP Base station.
Wifi_RLBASExxxxxx
  1. Click Connect.
  2. The NTRIP Base Station's Wi-Fi network is password-protected. When prompted, enter “racelogic” as the network security key / password.
Wifi_RLBASExxxxxx_password
  1. Connect to the network.

  2. Once connected, open an HTML browser and enter the IP address displayed on the front panel of the NTRIP Base Station (default IP is 10.10.10.1) to access its configuration page.

(If required)

The LTE/Wi-Fi Status area displays the LTE or Wi-Fi status for the NTRIP Base Station, depending on the configuration. 

LTE_WiFiStatus

Click the Change Settings button to configure the LTE or the Wi-Fi settings of the unit:​

LTE_WiFiStatus_Settings

The SSID of the NTRIP Base Station's Wi-Fi network.

This is the name that the unit will display when you select it from the available Wi-Fi networks on another device.

The IP address of the NTRIP Base station that must be entered in the HTML browser's address bar to access the configuration page. ​
 

You can also choose to have the NTRIP corrections sent via an LTE or Wi-Fi connection.

LTE

When you select LTE, you must enter the following information to configure the network for the NTRIP Base Station:​

  • The APN of the LTE Network​.

  • The username for that network​.

  • The password of that network​.

Wi-Fi

When you select Wi-Fi, you must enter the following information to configure the network for the NTRIP Base Station:​

  • The SSID of the Wi-Fi network​

  • The password for the Wi-Fi Network (this can be left blank if the network is not password protected).

(If required)

To configure the NTRIP Corrections, you must add the relevant information in the NTRIP Corrections Settings.

  1. Press the Change settings button next to the NTRIP Corrections heading to open the NTRIP Corrections settings.
     
     
NTRIPCorrections_ChangeSettings
  1. Enable the NTRIP Server.
  2. Enter the Server Name/IP Address, Port, Mount Point (correction data stream) and Password information (if required).
     
    Note: These details will be provided by your NTRIP Caster provider.
  3. Click the Save button.

    The NTRIP Base Station will attempt to connect to the NTRIP server using the provided details.
  • If there is a problem with the server details, the unit will briefly display an Invalid Caster Credentials message.
  • When it has connected to the NTRIP server, the unit will briefly display the RTCM Streaming message. 
  • The Configuration Page will be updated with the new settings and a connection status indication. The front display will also provide this information.

     

The NTRIP Base Station can either use the internal 4G modem via a Standard SIM card or use a Wi-Fi connection to acquire the NTRIP correction messages from the server. 

LTE_WiFiStatus

If you want to use the internal 4G modem, you must use your own Standard data SIM card.

Insert the SIM card into the SIM card slot in the compartment on the right side of the unit. 

 

 

When the unit is first powered on, it will automatically start as a configuration access point. 

The LCD on the unit will display a Wi-Fi hotspot name and an IP address that you must use to connect to and configure the unit.

  1. Use a mobile device or a computer with Wi-Fi.
  2. Navigate to the Wi-Fi settings on the device and select the NTRIP Base Station's hotspot (this is the serial number of the unit you wish to connect to.)
  3. Enter the Wi-Fi password: racelogic
  4. Use a phone or computer to open an internet browser and enter the IP address from the unit LCD into the address bar to open the unit's Configuration Page.
  5. Navigate to the bottom of the Configuration Page and the LTE/Wi-Fi Settings section.
  6. Click the Change settings button next to the section heading to open the LTE/Wi-Fi Settings for the unit.
  7. Select LTE to add the credentials for the network you want to use for the corrections.
  8. Click the Save and restart button.
     
    Note: The settings are retained after power cycles and the unit will always attempt to auto-connect to a configured Wi-Fi hotspot when it powers up.

    The unit will reboot and connect. When it is connected, the LCD will briefly display Wi-Fi Connected.

When the unit is first powered on, it will automatically start as a configuration access point. 

The LCD on the unit will display a Wi-Fi hotspot name and an IP address that you must use to connect to and configure the unit.

  1. Use a mobile device or a computer with Wi-Fi.
  2. Navigate to the Wi-Fi settings on the device and select the NTRIP Base Station's hotspot (this is the serial number of the unit you wish to connect to.)
  3. Enter the Wi-Fi password: racelogic
  4. Use a phone or computer to open an internet browser and enter the IP address from the unit LCD into the address bar to open the unit's Configuration Page.
  5. Navigate to the bottom of the Configuration Page and the LTE/Wi-Fi Settings section.
  6. Click the Change settings button next to the section heading to open the LTE/Wi-Fi Settings for the unit.
  7. Select Wi-Fi to add the credentials for the network you want to use for the corrections.
  8. Click the Save and restart button.
     
    Note: The settings are retained after power cycles and the unit will always attempt to auto-connect to a configured Wi-Fi hotspot when it powers up.

    The unit will reboot and connect. When it is connected, the LCD will briefly display Wi-Fi Connected.

     

    Notes:

    • Only a 2.4 GHz Wi-Fi signal is supported; 5 GHz is not supported.
    • If it cannot connect to the configured Wi-Fi hotspot on power-up, it will automatically restart and become a configuration access point again. 

 

If you need to connect your phone/ PC to the NTRIP Base Station after changing the LTE/Wi-Fi Settings, you can use the same hotspot and enter the new IP address (displayed at the bottom of the screen). The page will update with the new settings and provide a connection status indication. If the NTRIP Base Station cannot connect to the configured Wi-Fi hotspot on power up, it will automatically restart and become a configuration access point.

Survey

Before the NTRIP Base station can begin to transmit RTK correction messages, it must have a set reference location, either through a live survey or by loading a previously surveyed location.​

  1. Click the Change settings button to open the Survey Settings.
SurveySetup_Survey Time
  1. Select the survey duration:
  • 24 Hours
  • 12 hours
  • 1 Hour
  • 5 minutes
  • instantaneously​
  1. Click Save.
  2. Before the survey can start, you will be prompted to enter a name for the upcoming survey. 
SurveySetup_Enter Name
  1. Click Start Survey to start the surveying process.​

When the survey has been completed, the Current location will update to the new survey.

You can load this survey at a later time via the Change Location option.

  1. Click the Change Location button to choose a previously surveyed location for the NTRIP Base Station.
Load_Location
  1. Select the required location from the list of Surveyed Locations and click the respective Use​ button. 

You can view the surveyed locations on the map (if the device has a valid internet connection), rename the location, and delete it if you no longer need it by using the respective Map, Rename and Delete buttons for the relevant location. 

Click the Add new location button to create a new location by manually entering latitude, longitude and altitude.

The Corrections Output area displays how the RTK correction messages are being transmitted.​

Corrections Output

 

Click on the Change Settings button to access the following settings:​

Corrections Output_Settings

Set the RTK correction messages to either MSM4 or MSM7.

Set the RTK corrections to be sent via:

  • the external serial port

    OR
     
  • the internal radio (NBS24 variants only)​

Set the baud rate of the serial port.