Pass-By Noise Test - R41

Updated on Mar 4, 2026

The R41 Pass-By Noise test has a unique Test Setup ribbon, from which you can configure the test.

Pass-by-noise_TestSuite_R41_TestSetup
Pass-by-noise_TestSuite_R41_TestSetup_Test

Click on the Configure button to open the Settings window where you can define the parameters of the test.

Click on the Report button to create a report from the current test results.

Click on the Maths Channels button to open the Maths Channels window to configure unique maths channels. You can find more information about maths channels in the Test Setup section.

Click on the Save Settings button to save the current test setup and add it to the Saved Settings area in the Add Test window.

The test will also be added to the list under the Pass-By Noise Test button on the Home tab for easy access.

Click on the Export button to display a dropdown menu with the export options. You can export the selected results or line results to a .csv or a .txt file. 

Pass-by-noise_TestSuite_R41_TestSetup_Gate

If you are using an RTK solution to set start line(s), click the Add Start Line button to set a start line. This will add a virtual start line to the Chart and Map areas at the current location of the cursor. Once you have added a start line, you can specify the gate width.

Start Line 1 will be indicated by a green line. The currently selected gate is indicated by a dark blue line.

When you have added a gate, the name of the currently selected gate will be displayed in the name box. Click on the arrow in the box to see a dropdown list of all the added gates. The gates will be named according to the type of gate (if applicable) and the order it was added.  

Note: You cannot have multiple gates with the same name.

When you have added a gate, you can specify the gate width. The default gate width is 20 m.

Type the required width in the Width (m) value box. 

Click on the Rename button to edit the currently selected gate line.

Click on the Delete button to delete the currently selected gate line. 

Click on the Delete All button to delete all set gates for the session. 

Click on the Export button to export the created gate(s) as an .spl file. This file can be reused at a later date and with another VBOX product.

Click on the Import button to import a previously saved or provided .spl file. When the file is imported, the gates will be added in the order that they were saved in the .spl file.


Image missing

The Add button adds a column to the Test Results area. Click this button to open a dropdown menu where you can select a channel to display in the test results window.

When you select a column header in the Test Results area, the channel name will be displayed in the Channel box (the top box in the Data Column section). Some columns will have required channels and cannot be changed, but if you can change the channel, the Channel box will become a drop-down list with the available channels.    

Data column_SelectedColumn_DefaultChannel
Data column_SelectedColumn_EditChannel
Data column_SelectedColumn_DefaultChannel
Data column_SelectedColumn_EditChannel

When you select a column header in the Test Results area, and it is a changeable channel, the Condition dropdown menu becomes available. The conditions will depend on the test and selected channel.

Examples are:

  • Avg
  • Max
  • Min
  • Delta 
  • At Start
  • At End

The Sort Ascending button will sort the values in the currently selected column in the Test Results area in alphabetical order from A to Z.

The Sort Descending button will sort the values in the currently selected column in the Test Results area in alphabetical order from Z to A.


Image missing

Click on the Select All button to select every run in the Test Results area with one click.

Run -  Deselect All 

Click on the Deselect All button to deselect every run in the Test Results area with one click.

Click on the Deselect All button to deselect every run in the Test Results area with one click.


Image missing

Click on the Edit Data button to open the Session Data window and add various vehicle and test information, such as:

Pass-by-noise_TestSuite_R41_SessionData

Vehicle

  • Vehicle Model
  • Vehicle Number
  • Driver Name
  • Engine Model
  • Engine Number
  • Engine Capacity
  • Exhaust Model
  • Kerb Mass (kg)
  • Power (kW)
  • Idle RPM
  • Rated Engine RPM
  • Calculated Values

Measurements*

  • Front offset
  • Rear offset

Wheels/Tyres

  • Front 
    • Wheel Dimensions
    • Tyre Make
    • Tyre Dimensions
    • Tyre model
    • Tyre Pressure
  • Rear
    • Wheel Dimensions
    • Tyre Make
    • Tyre Dimensions
    • Tyre model
    • Tyre Pressure

Test

  • Test Date
  • Test Track
  • Test Facility
  • Comments

Conditions

  • Weather
  • Temperature
  • Track Temperature
  • Humidity
  • Wind Speed
  • Background Noise (dBA)

The vehicle offsets measurements are mandatory. The other data is optional and will not affect the test or test result.

Enter the front and rear vehicle offsets from the laser light trigger, or GNSS antenna if using GPS start/finish lines. 

The start of the test is deemed to be when the front of the vehicle passes the start line and the end is when the rear of the vehicle passes the finish line.

When in Offline mode, the Session Data will be saved into the VBOX file.  This information will be recalled every time the file is loaded into VBOX Test Suite.

When in Online mode, a newly created session will be populated with session data from the previous session.

To save time, you can import and export the session data for other sessions. When you have completed the Session Data, you can export the data to a .vbses file by clicking on the Export button in the Session Data window. The exported file will contain all the session data and can be imported into another session via the Import button in the Session Data window.


Image missing

Click on Help to automatically open an Internet browser and load the relevant section of the User Guide on the Racelogic Support Centre.

If you are creating a new test, the Settings window will open when you add the new test. This is where you can define the test parameters.

If you have already added an R41 Pass-By Noise test and it is open, you can click on the Configure button to open the Settings window to define or amend the test parameters.

Use the arrow buttons on the right-hand side of each parameter section to expand and collapse the section to view or hide the available settings.

Pass-by-noise_TestSuite_R41_Settings

With Laser Light Barrier:

Select the channel Trigger in the dropdown menu.

If you use a trigger as the start condition, the test will ignore any other trigger activations during the duration of the test.

With RTK Solution:

Select the relevant in the dropdown menu. 

As the test can be conducted in both directions, you can set 1 or 2 Start On lines in this setting. 
 

Start Line Offset (m)

Set the distance between the reflective strip and the Start Line (AA') in the test area. 

To prevent situations where the start line offset is less than the vehicle front offset to the antenna, the minimum value of the Start Line Offset (m) is 5 m.

It is recommended that the reflective strip is located 30 m after the Start Line.

Use the arrow buttons next to the value box to increase/decrease the value or type the required value directly into the box.  
 

End Line Offset (m)

Set the distance between the reflective strip and the End Line (BB') in the test area. 

Use the arrow buttons next to the value box to increase/decrease the value or type the required value directly into the box.  
 

Test Speed

Set the speed of the test (50 km/h by default).

The R41 regulation requires a different test speed if a motorbike has a low power-to-mass ratio.

Use the arrow buttons next to the value box to increase/decrease the value or type the required value directly into the box.  

Pass-by-noise_TestSuite_R41_Settings_StartConditions

With Laser Light Barrier:

Select the channel Trigger in the dropdown menu.

If you use a trigger as the start condition, the test will ignore any other trigger activations during the duration of the test.

With RTK Solution:

Select the relevant in the dropdown menu. 

As the test can be conducted in both directions, you can set 1 or 2 Start On lines in this setting. 
 

Start Line Offset (m)

Set the distance between the reflective strip and the Start Line (AA') in the test area. 

To prevent situations where the start line offset is less than the vehicle front offset to the antenna, the minimum value of the Start Line Offset (m) is 5 m.

It is recommended that the reflective strip is located 30 m after the Start Line.

Use the arrow buttons next to the value box to increase/decrease the value or type the required value directly into the box.  
 

End Line Offset (m)

Set the distance between the reflective strip and the End Line (BB') in the test area. 

Use the arrow buttons next to the value box to increase/decrease the value or type the required value directly into the box.  
 

Test Speed

Set the speed of the test (50 km/h by default).

The R41 regulation requires a different test speed if a motorbike has a low power-to-mass ratio.

Use the arrow buttons next to the value box to increase/decrease the value or type the required value directly into the box.  

Pass-by-noise_TestSuite_R41_Settings_StartConditions

Specify the channel with the input for Microphone 1.
 

Microphone 2

Specify the channel with the input for Microphone 2.
 

RPM

Specify the channel with the engine speed input. 
 

Gear

Specify the channel with the gear input.

Pass-by-noise_TestSuite_R41_Settings_Channels

Specify the channel with the input for Microphone 1.
 

Microphone 2

Specify the channel with the input for Microphone 2.
 

RPM

Specify the channel with the engine speed input. 
 

Gear

Specify the channel with the gear input.

Pass-by-noise_TestSuite_R41_Settings_Channels

Only when using a weather station, otherwise leave it blank.

Channel

Specify the channel with the Air Temperature.

If you select a channel, VBOX Test Suite will add a pass/fail column for Temperature in the results table to ensure that the ambient air temperature is within the specified range during each test. The default range is 5°C to 45°C.
 

Min (°C)

Specify the minimum temperature in the acceptable temperature range for the test. 

Use the arrow buttons next to the value box to increase/decrease the value or type the required value directly into the box.
 

Max (°C)

Specify the maximum temperature in the acceptable temperature range for the test. 

Use the arrow buttons next to the value box to increase/decrease the value or type the required value directly into the box.  

Pass-by-noise_TestSuite_R41_Settings_Temperature
Channel

Specify the channel with the Air Temperature.

If you select a channel, VBOX Test Suite will add a pass/fail column for Temperature in the results table to ensure that the ambient air temperature is within the specified range during each test. The default range is 5°C to 45°C.
 

Min (°C)

Specify the minimum temperature in the acceptable temperature range for the test. 

Use the arrow buttons next to the value box to increase/decrease the value or type the required value directly into the box.
 

Max (°C)

Specify the maximum temperature in the acceptable temperature range for the test. 

Use the arrow buttons next to the value box to increase/decrease the value or type the required value directly into the box.  

Pass-by-noise_TestSuite_R41_Settings_Temperature

Only when using a weather station, otherwise leave it blank.

Channel

Specify the channel with the Wind Speed.

If you select a channel, VBOX Test Suite will add a pass/fail column for Wind Speed in the results table to ensure that the wind speed, including gusts, doesn't exceed the maximum threshold at the height of the microphone during each test run. The default maximum is 5 m/s.
 

Max (m/s)

Specify the required maximum wind speed for the test. 

Use the arrow buttons next to the value box to increase/decrease the value or type the required value directly into the box.  

Pass-by-noise_TestSuite_R41_Settings_WindSpeed
Channel

Specify the channel with the Wind Speed.

If you select a channel, VBOX Test Suite will add a pass/fail column for Wind Speed in the results table to ensure that the wind speed, including gusts, doesn't exceed the maximum threshold at the height of the microphone during each test run. The default maximum is 5 m/s.
 

Max (m/s)

Specify the required maximum wind speed for the test. 

Use the arrow buttons next to the value box to increase/decrease the value or type the required value directly into the box.  

Pass-by-noise_TestSuite_R41_Settings_WindSpeed
Wide Open Throttle (dBA)

Specify the maximum sound level for the Wide Open Throttle tests.

Use the arrow buttons next to the value box to increase/decrease the value, or type the required value directly into the box.  
 

Steady Speed (dBA)

Specify the maximum sound level for the Steady Speed tests.

Use the arrow buttons next to the value box to increase/decrease the value or type the required value directly into the box.  

Pass-by-noise_TestSuite_R41_Settings_NoiseThreshold
Wide Open Throttle (dBA)

Specify the maximum sound level for the Wide Open Throttle tests.

Use the arrow buttons next to the value box to increase/decrease the value, or type the required value directly into the box.  
 

Steady Speed (dBA)

Specify the maximum sound level for the Steady Speed tests.

Use the arrow buttons next to the value box to increase/decrease the value or type the required value directly into the box.  

Pass-by-noise_TestSuite_R41_Settings_NoiseThreshold

You can rename a session tab by double-clicking the tab header. Changing the name on the session tab in the software will automatically change the name of the locally saved VBOX file (.vbo or .vbb).

By pressing the Edit Data button next to the name of the session in the Test Results area or on the Test Setup tab on the ribbon, you can add vehicle and test information to the session.

  • When in Offline mode, this information will be saved into the VBOX file, meaning that this information will be recalled every time the file is loaded into VBOX Test Suite.
  • When in Online mode, a newly created session will be populated with session data from the previous session.

This information will be included in the test report to make it easier to see under what conditions the test was conducted.

To save time, you can import and export the session information for use in other sessions (the entire range of data is exported, not just the visible screen).

Once the session information has been completed, you can export the data to a .vbses file. This file will contain all the session information that can then be imported into the open session information field.

Pass-by-noise_TestSuite_R41_Results

The Test Results area has the following default columns:

Run
Indicates which run number the results relate to, with run one being the first run completed.

There is also a selection box that, when ticked, includes that run in the graph and into the Average/Max/Min/Standard Deviation calculations. Once selected, a coloured square will appear to indicate which colour this run is displayed as on the graph.
 
Note: If you are loading a file in Offline mode, all valid runs will automatically be ticked.
Time (s)
The total time the run has taken.
Speed at Start (km/h)
The speed value at the start line AA’.
Speed at Mid (km/h)
The speed value at the microphone line PP’.
Speed at End (km/h)
 The speed value at the finish line BB’.
Acceleration (g)
Average acceleration value between AA’ and BB’.
Noise
Pass or Fail status when Mic1/2 Max is compared to the Noise Threshold value.

The software will automatically add columns based on any specified pass criteria.