| Technical | |
|---|
| Measurement range | 0 – 150 kg (1470.99 N) |
|---|
| Overload limit | 225 kg (2206.5 N) |
|---|
| Measurement accuracy (% FSO) | 1% |
|---|
| Zero balance/offset (%/rated output) | 2% FSO (*0.1 V) |
|---|
| Non-Linearity (%/rated output) | <±0.5% FSO |
|---|
| Hysteresis (%/rated output) | <±0.5% FSO |
|---|
| Output range | 0 – 5 V DC |
|---|
| Environmental | |
|---|
| Operating temperature range | -10°C to +40°C |
|---|
| Temperature effect on zero (%/rated output/C) | <±0.007%/°C FSO |
|---|
| Temperature effect on output (%/applied load/C) | <±0.005%/°C FSO |
|---|
| Power | |
|---|
| Voltages | 8.5 – 28 V |
|---|
| Current draw | 8 mA (typical) |
|---|
| Physical | |
|---|
| IP Rating | IP66 |
|---|
| Material | Stainless steel |
|---|
| Weight | Load cell: 435 g; bracket: 250 g; bolts: 50 g; total: 740 g |
|---|
| Cell dimensions (diameter x h) | 75 mm x 24.5 mm |
|---|
| Bracket dimensions (l x w x h) | 146.2 mm x 93.3 mm 19 mm |
|---|
Note: The pedal force transducer has a zero load output of approximately 0.1 V.